List how the fans will actually run
A parallel fan system needs an operating case for each expected combination. Mark which fan runs, which branch is isolated and which dust sources are active. The DOE fan sourcebook discusses combined fan curves and differences caused by duct arrangement [2]. Ask the designer to review the combined duty at the relevant system resistance.

Review the idle branch
Show the branch arrangement and the method provided to limit recirculation through an idle fan. Request the approved control sequence and the intended response if a branch changes state. The sourcebook identifies backdraft through idle fans as an arrangement issue [2]. Verify the actual installed device and responsibility with the designer.
Specify measurable acceptance cases
Provide production demand, duct layout and the actual fan curves used for selection. Agree which combinations will be checked and which pressure and airflow points will be recorded. Keep the fan selection considerations from the archive [1] tied to the actual system cases rather than adding nameplate airflow values.
FAQ. Can two catalogue airflow values be added directly?
Use the combined fan performance and actual system resistance. Catalogue duties from unrelated operating points cannot establish the resulting flow.